Ultraviolet-Visible UV-Vis Spectrophotometer
Ultraviolet-Visible UV-Vis Spectrophotometer
Product Features
● High-resolution C- T structure monochromator, good stability, reproducibility and accuracy.
● Advanced ARM microcomputer technology, excellent electronic circuit and signal processing, stable and reliable data, U disk data storage and export, software one-key upgrade, Bluetooth printing and other data output.
●Integrated aviation-grade aluminum alloy substrate, machined mirror seat to ensure long-term stability of the optical path.
● 7-inch color large-screen graphic liquid crystal display, with navigation menu interface design, clear operation commands, with special functions to prevent users from operating errors, users can operate without checking the user manual; touch screen + key double operation mode, with gloves can also operate.
● Strict manufacturing process and 32 key quality control points, so that each instrument is very durable.
● Large capacity memory, can store massive test data.
● Deuterium lamp, tungsten lamp, photocell, precision screw and other key devices are selected well-known and imported brands to ensure reliable quality of the instrument.
● Four-slot 10-50mm universal adjustable manual sample holder, convenient for different specifications of the cuvette test needs.
● Independent design of deuterium lamp, tungsten lamp replacement window, flange type positioning structure, easy to replace.
Product Function
Photometric Measurement: You can select the single-point test wavelength and test method you need in the range of 190-1100nm to determine the absorbance or transmittance of the sample. The concentration of the sample can also be read directly by inputting the standard sample concentration or concentration factor. 2, quantitative measurement: through the known parameter factor curve or automatically establish the standard solution curve, measure the sample solution of unknown concentration.
3. Qualitative measurement: set a wavelength range, scan intervals, and then measure the absorbance, transmittance, reflectance and energy of solid or liquid samples at intervals. The measured atlas can also be superimposed, scaled, smoothed, filtered, peak-valley detected, saved, printed, etc.
4. Time measurement: Time measurement is also called dynamic measurement. The sample is scanned according to the time range interval of absorbance or transmittance at the set wavelength point. The absorbance can also be converted into concentration or reaction rate calculation by inputting the concentration factor.
Enzyme kinetic reaction rate calculation. Can also be measured out of the map overlay, scaling, smoothing, filtering, peak valley detection, derivation and other map processing methods for your choice.
5. DNA/protein measurement: absorbance measurement is mainly carried out at 260nm/280nm/230nm/320nm, and the concentration and ratio of DNA and protein are obtained according to the calculation formula.
6. Multi-wavelength measurement: It is possible to set multiple wavelength points, and measure the absorbance or transmittance of the sample solution. N wavelength test wavelengths can be set to test the absorbance and transmittance ratio at a single wavelength.
7, instrument calibration measurement: built-in special wavelength larger allowable error calibration, transmission larger allowable error measurement, stray light measurement.
8. Auxiliary functions: deuterium lamp, tungsten lamp lighting cumulative time, deuterium lamp, tungsten lamp independent shutdown and startup, ultraviolet and visible light switching wavelength point selection, operating language selection, wavelength automatic calibration, Bluetooth function, etc.
9. Optional PC anti-control software package functions: quantitative measurement, qualitative measurement, time measurement, DNA protein measurement, multi-wavelength measurement, 3D graphics analysis, map overlay analysis, etc.
Specification:
model
|
FUZX5
|
optical system
|
single beam; 1200 strips/mm holographic grating
|
wavelength range (nm)
|
190-1100
|
spectral bandwidth (nm)
|
2
|
wavelength accuracy (nm)
|
±0.5
|
Wavelength Repeatability (nm)
|
≤ 0.1
|
Transmittance Accuracy (%T)
|
±0.3
|
Transmittance Repeatability (%T)
|
≤ 0.1
|
noise (%T)
|
0% line 0.2;100% Line 0.3
|
Drift (Abs)
|
≤ 0.001
|
Baseline Flatness (Abs)
|
±0.001
|
Stray Light (%T)
|
≤ 0.05 @ 220nm and 360nm
|
photometric range
|
0-200% T,-0.301-3A, 0-9999C(0-9999F)
|
test mode
|
transmission, reflection, absorbance, concentration, energy
|
light source
|
deuterium lamp + tungsten lamp
|
display
|
7-inch touch screen display (resolution 800*480)
|
system language
|
Chinese, English, Russian, Spanish
|
software upgrade
|
support U disk one-click upgrade
|
data output
|
U Disk, Bluetooth, USB Software Upload
|
Data Output Format
|
CSV
|
Operation Mode
|
Touch Screen
|
Sample Shelf
|
4-slot 10-50mm universal adjustable manual sample rack
|
host function
|
basic + quantitative + qualitative + time + DNA + multi-wavelength
|
printer
|
selection, support Bluetooth printing
|
power range
|
AC90 ~ 250V/ 50~60Hz
|
size (L×W×H)mm
|
470 × 330 × 210
|
weight (kg)
|
12 |
Standard Configuration
● Main Machine 1pcs,
● Power Cord 1pcs,
● Four Slots 10-50mm Universal Adjustable Manual Sample Frame 1pcs,
● 1cm Standard Quatz Cuvette 1 box (2pcs),
● 1cm Standard Glass Cuvette 1 box (4pcs),
● User manual 1pcs,
● Dust cover 1pcs.